Product Categories

DOA (Drug of Abuse) LC-MS/MS analysis kit

DOA (Drug of Abuse) LC-MS/MS analysis kit
CE-IVD certified and suitable for any kind of LC-MS/MS instrument
 

Zivak LC-MS/MS Psychoactive drugs analysis kit can be used in combination with the Zivak-Multitasker as well as manually. 

Zivak Psychoactive Drugs LC-MS/MS Analysis Kit is developed for quantitative detection of 15 selected psychoactive drugs from different drug groups in urine samples with a minimum sample preparation in 7 minutes. Main methods and procedures that have been selected are based on EN ISO 13485 and 98/79/EC.

 

Quantitative LC-MS/MS analysis kit for Psychoactive Drugs in urine.

Psychoactive drugs are chemical substances that affect the brain functions, behaviours and consciousness. These drugs can be used therapeutically to treat both physical and psychological disorders. Monitoring the concentrations of these drugs is very important issue for clinicians if they used for therapy. The analytic methods must be highly sensitive and selective for accurate and precise quantification of these drugs for therapeutic monitoring. Detection and quantification of these drugs can be performed using UV or fluorescence spectrophotometers, immunoassays and radio-receptor assays. Mass spectrometers coupled with chromatographic systems such as LC-MS, LC-MS/MS, GC-MS are more suitable for this purpose through their sensitivity and specifity.

Zivak Psychoactive Drugs LC-MS/MS Analysis Kit is developed for quantitative detection of 15 selected psychoactive drugs from different drug groups in urine samples with a minimum sample preparation in 7 minutes. Main methods and procedures that have been selected are based on EN ISO 13485 and 98/79/EC.

DOA (Drug of Abuse) LC-MS/MS analysis kit 0
LC-MS/MS parameters : contact for more details

Storage & Stability

  • Please check the labels on reagent bottles. Reagents of this kit contain hazardous material may cause eye and skin irritations. This analysis kit can be shipped at room temperature.
  • After arrival, reagent 2 and standard 1 must be stored at -20 °C.
  • Synthetic Urine must be stored at 2-8 °C
  • All other components must be stored at room temperature. Please make sure that you keep reagent 1 at room temperature otherwise it will become unusable.
  • All components are guaranteed until expiry date when stored at recommended temperatures and used as described in these instructions.

Preparation of Zivak Calibrators and Controls : contact for more details

 

Materials Supplied

Order No

Volume

Content

ZV-2001-02R1-20

2 x 37 ml

Reagent 1, Contains base

ZV-2001-02R2-20

 2x 45 ml

Reagent 2, Contains internal standards

ZV-2001-02MA-20

 1x 0,5 L

Mobile Phase A, Contains organic solvent and acid

ZV-2001-02MB-20

 1x 0,5 L

Mobile Phase B, Contains organic solvent and acid

ZV-2001-02WB-10

 2 x 1 L

Washing solution, Contains organic solvent

ZV-2001-02SU-10

 1x 10ml

Synthetic Urine

ZV-2001-KK-20

    1x 1 pc

User Guide

 
 
Materials Required But Not Supplied

Order No

Volume

Content

ZV-2001-02S1-20

1 x 1 ml

Standard 1, in organic solvent

ZV-2001-02C1-20

1 pcs

Zivak Psychoactive Drugs Urine LC-MSMS Analytical Column

 

Zivak General Catalog

Download Zivak General Catalog PDF